I am trying to install Teradata connection in a virtual machine of Windows Server 2012.
I tried multiple times but I still got the timed out error: No response received when attempting to connect the Teradata error.
I tried connecting through SQL assistant and python teradata module. Below is what I have tried based on resolutions found on web search and none of them works
1. Close the firewall
2. Change the odbcLibPath (in Python)
3. Reinstall .NET framework
4. Extend the time awaiting for response
5. Seeking resolutions around odbc.ini and odbcinst.ini but for Windows specifically, I can not find any resolution.
I have also not be able to find much difference between the configuration on the virtual machine and that on my local desktop which works well.
I felt I have run out of possible solutions at the moment. Appreciate any help in this.
Related
We are using a Self-Hosted Integration Runtime for Azure Data Factory.
On that machine there was installed an Exasol ODBC driver of version 6. We wanted to upgrade the driver, deleted an old one and installed a new driver of version 7.
Weird thing is that now in Exasol logs we can see that Data Factory is sometimes connecting via driver version 7, and sometimes via driver version 6.
I made an experiment and deleted Exasol ODBC driver from the machine completely. After that Data Factory still was able to connect to Exasol using the driver I just deleted.
Looks like drivers' DLLs are cached somewhere. What can it be?
Update 1
I captured following actions in Process Monitor when Data Fatory connected to Exasol with ODBC driver of version 6:
Where these C:\Config.Msi\3739be5*.rbfASolution-6.1\ODBC\ DLLs may come from? There is no C:\Config.Msi\ directory on the machine.
Update 2
I noticed that when I test connection via Microsoft Integration Runtime Configuration Manager on the machine or in Data Factory Linked Service, then connection is always performed with ODBC driver of version 7.
But when I test connection via Data Factory Dataset, then in some cases connection is done with ODBC driver of version 6.
You could check the registry but clean at your own risk. An alternative might be the SysIternals tools, Process Monitor or Process Explorer which might help you get to the bottom of this. Install them on the SHIR VM if you are allowed to. Process Explorer in particular is a bit like SQL Profiler (if you've ever used that) so will be able to tell you which registry keys external processes are using. It will give you a lot a lot of information so you will have to make judicious use of timestamp and filtering. The proposed steps:
Start a trace using Process Monitor
Start a pipeline using the Exasol driver
Wait til it completes (or at least you know it has started)
Stop the Process Monitor trace Spend time going through the millions
of records it has captured, trying to filter down, or search for your
process
An alternative would be to build a clean SHIR and install only the new driver. Then swap it in for the old one. You may have to get the new SHIR added to the firewall if this is an issue for you.
Honestly I would propose both of these approached in parallel for a production problem. Procmon / Process Explorer can be quite labour and time expensive but should help you get to the bottom of the issue. Building a cleaner SHIR is probably a safer option in the long-term, but requires new infrastructure.
It may sound silly, but rebooting the server where SHIR is working solved the problem.
We noticed, that this server was running for more than 30 days, and decided to reboot it. Maybe restarting Integration Runtime service itself would also help, but we didn't do it.
Thanks to everyone for you help.
I’m recieving this error when I try to start Cosmos Emulator 2.7.2.0:
Tried it on a fresh win10 machine, and it's working here. Any ideas on what might course this?
I tried all the suggestions in this article.
Looking at the etl file didn't give my anything either.
It's the first time I try to install it on my machine.
-- UPDATE --
I opened the dmp file, and found this:
Loading Dump File [C:\Users\xxx\AppData\Local\CrashDumps\Microsoft.Azure.Cosmos.StartupEntryPoint.exe(1).12596.dmp]
User Mini Dump File: Only registers, stack and portions of memory are available
Symbol search path is: srv*
Executable search path is:
Windows 10 Version 18363 MP (12 procs) Free x64
Product: WinNt, suite: SingleUserTS
18362.1.amd64fre.19h1_release.190318-1202
Machine Name:
Debug session time: Mon Jan 20 09:35:26.000 2020 (UTC + 1:00)
System Uptime: not available
Process Uptime: 0 days 0:00:02.000
................................................................
..................................
This dump file has an exception of interest stored in it.
The stored exception information can be accessed via .ecxr.
(3134.41b0): Unknown exception - code c000000d (first/second chance not available)
For analysis of this file, run !analyze -v
ntdll!NtWaitForMultipleObjects+0x14:
00007ff9`562fcc14 c3 ret
0:000> .ecxr
rax=0000000000000000 rbx=0000000000000000 rcx=0000003629dfd270
rdx=00000000e6bc7d4e rsi=0000000000000000 rdi=0000000000000000
rip=000000006748b0ec rsp=0000003629dfd190 rbp=0000000000000000
r8=000001ba53134730 r9=0000000000000000 r10=0000000000000026
r11=000001ba6d7662e0 r12=0000000000000004 r13=000001ba6d7974d0
r14=0000000000000000 r15=0000000000000000
iopl=0 nv up ei pl zr na po nc
cs=0033 ss=002b ds=002b es=002b fs=0053 gs=002b efl=00000246
msvcr80!_invalid_parameter+0x6c:
00000000`6748b0ec 488d4c2440 lea rcx,[rsp+40h]
Seems like something is wrong with my version of msvcr80
This may be caused by corrupted performance counters on your machine.
To fix your performance counters try the following.
Open cmd as administrator
Run "lodctr /R" (must use capital R)
If this doesn't work, see this link here that shows other options to reset your counters. Older article but works the same on Windows 10.
https://answers.microsoft.com/en-us/insider/forum/insider_wintp-insider_perf/possible-performance-counter-problem-on-win10/3a5c22cb-1425-4d26-99e7-4ec46940b9a1
btw, one more option here, is to run the emulator in a Docker container. The docs on that are in that article you referenced in your question.
Hope this is helpful.
For me this confusing error message simply meant that I needed to use another port! Or fix problems with the default 8081 one (read update 2 way below).
Here's the text of the error so that it's searchable:
Error: multiple attempts to restart one of the Azure Cosmos Emulator
processes were detected. The emulator will shutdown. If the problem
persist please try uninstalling the Azure Cosmos Emulator, remove the
CosmosDBEmulator directory from your %%LOCALAPPDATA%% and reinstall.
You can also reach out to the Azure Cosmos team using the 'Feedback'
link in the Data Explorer browser window.
Details:
In my case this happened by itself after Windows 10 updated 2004. I swear something breaks in Cosmos DB emulator every feature update!
For me there were no crash dumps and rebuilding performance counters didn't help. In the Event Viewer for System I've noticed this error A LOT:
Unable to bind to the underlying transport for 127.0.0.1:8081. The IP Listen-Only list may contain a reference to an interface which may not exist on this machine. The data field contains the error number.
No solutions for this error helped, so I first used netstat -ao to see if any program is already listening at 8081. Nope.
Then I used the "Port listener" utility from the www, and it turned out it can't listen to 8081 either, not even under admin rights!
Since I couldn't fix this 8081 problem at all & turning off Windows Firewall didn't help, I simply started the Cosmos DB emulator at a different port and it worked!
C:\Program Files\Azure Cosmos DB Emulator>Microsoft.Azure.Cosmos.Emulator.exe /Port=18001
If you've configured cosmos db to be started automatically on system startup, make sure to update that script as well.
In my case this cmdline got me into the Data explorer, but it wasn't actually working. The "Explorer" part of it was "fetching offers" infinitely. I had to again uninstall Cosmos DB emulator, clean this folder: %LOCALAPPDATA%\CosmosDBEmulator, reboot, install again without starting at 8081, and only start at the new port.
Cosmos DB devs, you're awesome people, but this is too much hassle. And if you can't use the port just say so, you don't have to be cryptic!
UPDATE:
This worked, but I forgot to update the start up script to use the new port, and noticed that after one more reboot the cosmos db started on 8081 without issues. What??! But it wasn't just any old reboot - I already did several of them before and they didn't help. This reboot may have been special in that it came after Windows found one more update (kb4576478), probably realizing it's now needed since I'm at version 2004, installed it, and THAT reboot (or the kb4576478 update specifically) fixed the 8081 problem, whatever it was. Yikes!
UPDATE 2:
Had another port-related problem with another tool. Ugh. Found this solution (see "General workaround") https://superuser.com/a/1568476/251491 This page's accepted answer also mentions the magic of multiple reboots.
Finally got it working!
By using WinDbg and opening the dmp files %LOCALAPPDATA%\CrashDumps, I found out that a dll called perf-MSSQL$SQLEXPRESS-sqlctr10.1.2531.0.dll was the root cause.
By deleting this in the %WINDIR%\System32 the error was "fixed" and I can now run the emulator.
I'm using sqlAnywhere 5.0 to create ODBC with third parties software house
I'm running it on windows XP without any error / problem
but 8/4/2014 Microsoft announce to stop service for windows XP
then our company migrate all client PC to windows 7x64
Now the application always hang and closed itself
I would like you suggest what can I do, I'm trying to test under SQL Anywhere 12.0 but I cannot config ODBC to open application
I also attached a picture (ODBC from rtdsh50.exe)
Start command is "C:\Starlims8\SqlAny50\Win32\rtdsk50.exe -d -c4000"
Please advise, Thank you in advance.
According to the image, you are using the version 5 runtime engine. This software is almost 20 years old... I am not surprised you are having trouble getting it to run on Windows 7.
It doesn't look like you are providing a database file on the startline in the ODBC configuration. Are you providing this somewhere else? What does your actual connect string look like in the application?
Version 12 will probably not work, since your application was written for version 5. However, to even have a chance, you have to rebuild the version 5 database in version 12 format and then replace the SQLA version 5 ODBC data source with a version 12 one with the same name.
Is this an application that you/your company wrote or is it a third party app. you purchased? Is it a 16 or 32 bit application?
Also, I would suggest setting the application up to run in compatibility mode as well as running it as an administrator.
I've created some Web API methods in .NET 4 / Visual Studio 2010 (and have now ported it to VS 2013 RC).
I want to consume them from a Windows CE / Compact Framework app using RestSharp.
Regardless of how I call these methods, though, I need to know the IP Address to use for the app running the Web API methods. I can access it from a browser using "localhost" and the port number Visual Studio displays when running the View for the Web API project in the browser (works fine, returns XML in Chrome).
But: how can I call it from my Windows CE / Compact Framework app? The emulator in which I run it doesn't believe that it and localhost are really on the same machine, so I can't use that, nor the machine's actual IP address as, again, it is delusional about who/where it is.
So: what is the workaround? How can I test this?
More details about this can be seen here: RFC on HttpWebRequest vs RESTSharp from Windows CE / Compact Framework 3.5
UPDATE
Vasily, my guess was that you meant for me to do this:
...but that led to this:
Note: I get the same when I choose the other option from the dropdown asociated with the "Enable NE2000 PCMCIA network adapter and bind to:" czechbox, namely "Intel(R) 82579LM Gigabit Network Connection".
And trying to install http://go.microsoft.com/fwlink/?linkid=46859 (both the 64-bit and the 32-bit flavors) slapped me with:
So tell me, I implore: Is there balm in Gilead, so that there may be joy in Mudville tonight?
UPDATE 2
In step 6 (bullet 6), I did this:
...which got me first a message that the software didn't install correctly, with the option to retry or assert that, no, everything is really fine (I chose the latter), but then this:
...IOW, I don't make it to step/bullet point 7
Then again, this Peek cat did warn, "Note that this is very much a “works on my machine” experience. If it burns your house down, don’t hold me responsible."
My house didn't burn down (I don't think - I'm not there right now), but the process to extract the file did fail ignominiously.
You can use workstation network card by the emulator. Todo it you have to select "Use installed network card" checkbox and select the card from the list. after that you can use the workstation ip.
This was helpful for me:
Windows Virtual PC and the Microsoft Device Emulator
I've had to use it more than a couple of times.
I saved the file as a PDF to my network folder, so it took me a while to find the link.
I have been given an ad hoc reporting tool from another individual that has successfully deployed it to the field. He uses Web Logic servers and an Oracle database.
I tried to deploy the same application in my local environment (WAS 7 and Oracle). The first report runs flawlessly. However, when I run the second (or third or fourth) report, I get a very strange error: the second report is appended to the first report.
There is nothing in the code to account for this. This problem can be temporarily solved by stopping and starting the servers every time a report is run (obviously not a real solution). I think this has something to do with data sources and cached information. I then took a step back and tried to deploy it to a Tomcat server. It works perfectly, just like it does in the field. So my question is: are there any known issues between WAS 7 and Oracle 11g that could be causing this kind of problem? Any information would be very helpful.
Please ask about any specifics you may want to know and I will do my best to provide that information.
Thank you for your time.
EDIT: For anyone else looking into this, the problem was due to an incompatibility with the proprietary Oracle calls and Websphere. Once the application was edited to use only JDBC calls, everything works perfectly. Thanks.
This ended up being a incompatibility with using proprietary Oracle calls and Websphere. It was fixed by changing all of proprietary call to normal JDBC calls.