I'm trying to create a hologram that is shared among multiple Hololenses by following Microsoft's Holograms 240 tutorial at https://developer.microsoft.com/en-us/windows/holographic/holograms_240
The network connection is working fine, and I have all the correct permissions in my project settings. The issue is that aside from a rare occurence, the call to WorldAnchorTransferBatch.ExportAsync() will fail with a SerializationCompletionReason.UnknownError and print out "Failed to world lock serialization failed"
I haven't been able to find any information about this error in my searching. Does anyone know what the cause of this could be?
Related
I'm trying to open the Artifactory Users Management page, following the Admin->Security->Users tab.
Then I'm getting the following error:
Any idea of what might be causing it? Also, which log I can check this? Couldn't find anything yet.
The server error generally indicates there is problem fetching the user details from Artifactory. This can happen due to any of the following reasons:
when you have a high volume of users and the request is timing out.
There is a chance that you might have created a username with a
special character which is not allowed (using the REST method or some
other method)
There is an issue with the backend database
And the best place to troubleshoot is to first check the request log a good valid entry looks like below:
20200715164402|104|REQUEST|165.225.104.49|admin|GET|/ui/users|HTTP/1.1|200|0
Next check the artifactory.log file for java stack or check catalina.out under tomcat/logs directory.
When I load my docker shiny app domain name in the browser, it crashes (greys out) and I get this "ERROR: [_parse_http_data] invalid HTTP method".
I have developed an web application that consists of a shiny app (has a login feature connected to an RMySQL database), a website and a mariadb database. I put them together in a docker-compose file and tested it on my local computer and it works fine. I then proceeded to deploy them in a Kubernetes cluster in GCE and that was also successful. I used cloudflare to install a ssl certificate for the shiny app domain (i.e. trnddaapp.com). Now when I load the shiny app domain in the browser it appends the https and loads the app successfully but after about a minute it crashes (greys out). I loaded the shiny app external ip with http and this doesn’t crash.
The closest solution I have come to is https://github.com/rstudio/shiny-server/issues/392 but there doesn't seem to be any other solution to my problem. I would be grateful if anyone help me resolve this problem.
This is the error message I get when I check with kubectl log [app pod name], I get this error:
ERROR: [_parse_http_data] invalid HTTP method
ERROR: [_parse_http_data] invalid HTTP method
ERROR: [_parse_http_data] invalid HTTP method
I expect the app not to crash when the shiny app domain (trnddaapp.com) is appended with the https.
Let's start with the analysis of the error message, it says:
[_parse_http_data]
So we know that your app is receiving something, but it doesn't understand what it is (it may be a malformed HTTP/1.0 or HTTP/1.1 or even binary data) then we have an
invalid HTTP method
Now we are sure it is not a HTTP/1.X call but a stream of (non recognized) data.
We now know is not the instance since it "deploys" and "delivers" the service, but something inside that is just breaking.
There are a few things that may be happening, since it runs in your local machine (where I am assuming it has access to more resources, especially memory) it may be an issue of resource allocation and that once ran in a container, it could be possible that it empties its allocated amount of resources and breaks (perhaps a library that is called in real time that uses a chunk of memory?) but we won't be sure unless we can debug it inside a container, so could it be possible for you to add a debug library that records your requests to see if it parses all of those and at some point in time it stops and why? I know a person from R-Studio created a httpuv that logs every request this can be done as in:
devtools::install_github('rstudio/httpuv#wch-print-req')
And after that, maybe share the output and see why the application is behaving like that and killing its own service.
I really thank you in advance, hopefully with those logs we may be able to shed more light into this matter.
Thanks once again!
-JP
I am learning tosca and currently we are trying to run a regression test suite for a legacy Java Swing application.
My Test suite contains 4 modules (in JTree) and it is getting failed while clicking a node.
The Error I received on the module is,
at.tosca.javaengine.common.exceptions.ControlException: node or
node-path not found! Detailed information contained in
'JavaEngineException.txt above message is displayed in Executionlist
JavaEngineException.txt
22-11-2017 - 17:56:37: IExecWrapperInterface_connectToControl
at.tosca.javaengine.common.exceptions.ControlNotFoundException: Unable
to find control Index=3;ClassName(s)=[javax.swing.JTable];.
at.tosca.javaengine.server.tree.ComponentSearch.getComponent(ComponentSearch.java:218)
->at.tosca.javaengine.server.AbstractJavaEngineCore.findComponent(AbstractJavaEngineCore.java:1129)
->at.tosca.javaengine.server.AbstractJavaEngineCore.connectToControlInternal(AbstractJavaEngineCore.java:936)
->at.tosca.javaengine.server.AbstractJavaEngineCore.connectToControlInternal(AbstractJavaEngineCore.java:922)
->at.tosca.javaengine.server.AbstractJavaEngineCore.connectToControl(AbstractJavaEngineCore.java:313)
->at.tosca.javaengine.server.JavaEngineCore.access$101(JavaEngineCore.java:25)
->at.tosca.javaengine.server.JavaEngineCore$2.runInternal(JavaEngineCore.java:69)
->at.tosca.javaengine.server.control.WorkerThread.run(WorkerThread.java:69)
->java.lang.Thread.run(Unknown Source)
->JNIServer::CallVoidMethod
->CJNIServer::CallVoidMethod
22-11-2017 - 17:58:58: IExecWrapperInterface_setValue
at.tosca.javaengine.common.exceptions.ControlException: node or
node-path not found!
at.tosca.javaengine.server.control.swing.GenericTreeControl.setValueLegacy(GenericTreeControl.java:339)
->at.tosca.javaengine.server.control.swing.GenericTreeControl.setValue(GenericTreeControl.java:88)
->at.tosca.javaengine.server.AbstractJavaEngineCore.setValueInternal(AbstractJavaEngineCore.java:1195)
->at.tosca.javaengine.server.AbstractJavaEngineCore.setValue(AbstractJavaEngineCore.java:686)
->at.tosca.javaengine.server.JavaEngineCore.access$401(JavaEngineCore.java:25)
->at.tosca.javaengine.server.JavaEngineCore$5.runInternal(JavaEngineCore.java:114)
->at.tosca.javaengine.server.control.WorkerThread.run(WorkerThread.java:69)
->java.lang.Thread.run(Unknown Source)
->JNIServer::CallVoidMethod
->CJNIServer::CallVoidMethod
NOTE : The same Test suite is working in some other machine and not here. Both are same operating System.
This is a bit confusing.
Looks like you are connecting to a JTable and then trying to select a node? Are you sure Tosca is finding the correct control on both machines? (Index=3 does not sound like a stable identification.
The problem was TOSCA is faster than our application :)
Meaning: The frame was not loaded at the time when TOSCA was trying to scan the next page causing the error, the specific node was
not found.
Solution: I added a TBoxWait with extra seconds, after that this is working fine.
I am facing this error since some time, it is very intermittent in nature so, unable to understand why this error and what needs t be done t fix this.
Issue:
We have a workflow 4.5 WCF service. Everything goes well, but intermittently we see suddenly that a workflow instance gets suspended with an error in the table "DurableInstancing.InstancesTable"
The error is "Keyword Not supported: 'DB Name,1433';Initial Catalog'.
Since most times this ust workd fine without any error, I do not think this problem is related to web.config entry for connectionstring. Most times the workflow completes without any error. We have verified multiple times that the connection string is proper and there is no issue with parsing the connection string.
I suspect this issue is happening while Workflow instance is being recreated from persistence storage, and because some reason it is unable to recreate , the workflow is getting suspended with this error in DB.
I really appreciate any help in getting us through this error.
Thanks,
GD
What we found was it was an issue with permission in Database. We gave "dbo" user permission to the workflow database, and after that we have not seen this problem occur again. Has the error or exception that gets logged in the table is mre informative then it would have been better.
Thanks,
GD
I am currently trying to get search working in my Tridion 2011 installation. I read in another article that I should run the TcmReIndex.exe tool in the Tridion/bin folder to re-index all my sites. So I tried this and it failed with a message box giving the following details
Unable to get list of Publication items.
Unable to Intialize TDSE object.
The wait operation timed out
Connection Timeout Expired. The timeout period elapsed while attempting to consume the pre-login handshake acknowledgement. This could be because the pre-login handshake failed or the server was unable to respond back in time. The duration spent while attempting to connect to this server was - [Pre-Login] initialization=21054; handshake=35;
The wait operation timed out
A database error occurred while executing Stored Procedure "EDA_TRUSTEES_GETTRUSTEEETOKEN"
I have four fairly large publications (100 000+ items in total) which I am trying to index.
Any ideas?
Whenever I get "Unable to Intialize TDSE object." errors, I typically write a small test script using VBScript, and try running it on the CMS server. Whilst this does not directly solve the problem, it often gives some insight into the issue by logging information in the event viewer. Try creating a test.vbs file as follows and running it:
Set tdse = CreateObject("TDS.TDSE")
tdse.initialize()
msgbox(tdse.User.Description)
Set tdse = Nothing
If it throws any errors, please let me know, and it may help us solve the problem. If it gives you a popup with your user description, then I am completely barking up the wrong tree.
I haven't come to anything conclusive but it seems like my issue may have been a temporary one as it just started working. I did increase all timeouts in Tridion MMC > Timeout Settings by 100 times their amounts but I suspect that this wasn't the issue, when it works the connection is almost instant.
If anyone else has this issue
Restart the computer the content manager is installed on, try again.
Wait an hour or two, try again.
Increase timeouts, try again.