Tridion 2009 SP1 TcmUploadAssembly not able to overwrite existing TBBs - tridion

I am using the TcmUploadAssembly utility in a post-build event but am receiving the following error from the tool.
Error 1 Name must be unique for items of type: Template Building Block
within this Folder and its BluePrint context. Source or sources of
conflict:
tcm:5-200-2048. C:\Projects\Project1\src\Tridion\TBBs\EXEC Compound
Templates
The TcmId given refers to the Assembly stored in Tridion which I would expect because that is what I am overwriting. In the past this "just worked". Am I missing something?
Notes:
My user is an admin
The Tridion instance is on my network so I am using credentials in context.
I have specified all settings via the command line (no config.xml is used)
Any ideas?

I would say check your Blueprint context (i.e. the Publication you are in). This error means you are trying to create the TBB, yet there is already an item with the same name probably somewhere down in the Blueprint child Publications.

Classic writing out the problem and the problem solves itself...
I discovered the folder is set in the AssemblyInfo as well and I had the folder set incorrectly on the command line (Blueprinting issue).
I ran into a second problem however, if I set uploadpdb:true on the command line I receive this error
Error 1 Could not write file: c:\Temp
Setting uploadpdb:false resolves the issue.

Related

Where does BizTalk keep dlls?

I am having some trouble with BizTalk saying a schema doesn't exist when it does exist.
I can see it in the BizTalkMgmtDb using
select * from bt_documentspec where msgtype like '%myschema%'
I can see it in the BizTalk Server Administration Console > <All Artifacts> > Schemas > My Schema.
This paragraph is optional. I'm only including it so you know I already tried the answer you get when you google this problem.
The exact error message I get is something like "This Assembler cannot retrieve a document specification using this type" which if you google that tells you the schema is either not deployed or the root element you're using exists in two separate namespaces so you should supply a DocSpecName on the SendPorts XMLTransmit 1 2.
I've also tried reinstalling the dll that contains the problem schema into the GAC as per the answer to this question. That didn't work either but now I have more questions anyways.
if I do gacutil -l none of my assemblies are listed there.
So I was wondering what does this even do?
Because those assemblies are not listed under gacutil -l. Also when you look at those assemblies
it shows a source location and a destination location.
Why? Why not just THE location? I can't even find %BTAD_InstallDir% on my computer so there are a minimum of 4 possible locations where this schema dll might be.
source location
destination location (%BTAD_InstallDir%)
"the GAC"
wherever it actually is because there doesn't seem to be a %BTAD_InstallDir%.
So if I want to "update the GAC" to make sure this schema is there how do I do that? What dll is BizTalk ACTUALLY using? The one in %BTAD_InstallDir% or the one in the GAC?
BizTalk 2010.
It has nothing to do with where the DLL is, it has to do with the fact that either
The XML payload namespace and root node does not match any schema
You have two or more schemas with exactly the same namespace and root node that match.
If you don't have any namespace on the XML, then it will try and match on Root node only, but again if you have more than one schema with the same root node, it will fail.
What you need to do is look at the suspended message and look at it's context properties and see what it's Message Type is, and compare that against the schema in BizTalk. There should be exactly one that matches.
vs
But to answer your question,
The source location is usually just the path of where the DLL was when it was initially imported in Dev.
the %BTAD_InstallDir% is the directory you chose when importing a MSI, the default location is C:\Program Files (x86)\Generated by BizTalk. However that is just where it puts it initially
Yes, in the end the actual one it uses will be in the GAC, which is under C:\Windows\Microsoft.NET\assembly\GAC_MSIL
Note: If the DLL has been previously been deployed and you are deploying a new one then make sure you restart the host instances afterwards, as it will cache DLLs in memory for a period.

Circular file references are not allowed Dnn 7+ in TFS 2013

I am using DNN 7.3 for a website project which is a combination of VB and C# codes. I use visual studio 2013 to build the project.
If the MSBuid Option in property page is configured to Allow this Precompiled site to be updatable and the project is published.
There will be a successful built. But when it is checked in to the TFS, the following exception will be thrown:
/compiled/DesktopModules/Admin/Security/manageusers.ascx (8): Circular file references are not allowed.
/compiled/DesktopModules/Admin/Security/manageusers.ascx (67): Unknown server tag 'dnn:profile'.
/compiled/DesktopModules/Admin/Security/EditUser.ascx (5): Circular file references are not allowed.
/compiled/DesktopModules/Admin/Security/EditUser.ascx (163): Unknown server tag 'dnn:Profile'.
/compiled/admin/Users/ViewProfile.ascx (4): Unknown server tag 'dnn:Profile'.
Also, when I checked Use Fixed Naming and Single Page Assemblies together with the Allow this Precompiled site to be updatable. it will throw:
ASPNETCOMPILER: Object reference not set to an instance of an object.
when I searched online, I was given two options from this blog.
I have tried the two but still having the same error.
I don't know what I am doing wrong.
Please look at [here] (http://ellisweb.net/2009/12/fixing-the-circular-file-references-are-not-allowed-error-in-asp-net/) for the explanation why you would see this error, simply speaking, if you have the following setup:
/folder1/Control1.ascx > References Control2
/folder2/Control2.ascx > References Control3
/folder1/Control3.ascx
This means that the folder1 dll will reference the folder2 dll which will again reference the folder1 dll, causing a “circular file reference”.
The solution is try to rearrange all controls under each folders, sometimes, you have to make a problem user control copied over to multiple folders to prevent such circular calling.
I changed The Clean WorkSpace property of TFS Build Process Parameters to false.
The error just disappeared and I was able to build successfully into TFS Drop folder. I don't know why this solves the problem but the problem was resolved.

Unable to create the workspace '' due to a mapping conflict

I am using TFS 2013 Build Server.
Getting the following Error
Exception Message: Unable to create the workspace '' due to a mapping conflict. You may need to manually delete an old workspace. You can get a list of workspaces on a computer with the command 'tf workspaces /computer:%COMPUTERNAME%'.
Details: The path F:\GDC\Bin is already mapped in workspace ''. (type MappingConflictException)
I have multiple build Definition which refers to common binary folder
Source Setting for Build definition BD1
Source Control Folder Build Agentfolder
$/Common F:\GDC\Bin
$/Project1 $(SourceDir)
Source Setting for Build defination BD2
Source Control Folder Build Agentfolder
$/Common F:\GDC\Bin
$/Project2 $(SourceDir)
Source Setting for Build definition BD3
Source Control Folder Build Agentfolder
$/Common F:\GDC\Bin
$/Project3 $(SourceDir)
This occurs (as the error suggests) when you have a workspace clash on the build server. Workspaces are saved as configuration values in the TFS database so clashes are possibly caused by:
you have created a new build definition with the same name as a previous build definition.
some part of your workspace name (or an artifact within your project) is over 260 chars
build definition is not using $(sourcedir) macro in System Settings tab
More details are explained in this article
Work-around:
Rename your build definition to something unique.
Here is how I did it:
First, tried to list the workspaces on the server in question. I tried through both Visual Studio UI and command prompt: tf workspaces /computer:. The workspace that is mentioned in the Exception message did not show up in the list.
Downloaded and installed Team Foundation Sidekicks 2015 from http://www.attrice.info/downloads/
When the app installed, opened and connected to tfs server.
Selected the computer name from the dropdown, cleared the Owner name (VERY IMPORTANT!) dropdown from the dropdown and changed Last access date to a date few years ago.
Clicked Search button. The list of workspaces appeared. This time I could see the workspace that was mentioned in the Exception message.
Selected the workspace that is mentioned in the Exception message and clicked Delete button.
It appears that when I login to the build server and ask for the workspaces list, tfs only shows me the workspaces of which I am the owner. The temporary workspaces that build process creates were not assigned to me and therefore I could not see them. Team Foundation Sidekicks 2015 did show me all of the workspaces.
Note: I used TFS2015 in this exercise.
So you have a Workspace conflict.
The easiest way to explain to fix this is to delete your workspaces and make them over again.
You'll need to use the TF tool.
TF /workspace /delete....
There is a TFS sidekicks tool that should be able to do this for you with a GUI.
http://www.attrice.info/cm/tfs/
The reason was (for me) that I have cloned the build definitions. So every "Build Agend Folder" in Source Settings points to the same target folder.
Solution was to change the Build Agent Folder to something special for each build.
e.g. $(SourceDir)\project1
$(SourceDir)\project2 etc
I had the same problem. My solution was that in Edit Build Definition > Source Settings, a Build Agent Folder was not prefixed with $(SourceDir), but instead the full path on my local machine.
I changed the path to be prefixed with $(SourceDir, and my problem was solved.
I have rename build definition name and it started working.

Tridion Copy/Paste In the same org item causes TCM54 Error

We are experiencing a strange issue after upgrading from Tridion 2011 GA to 2011 SP1 HR1. When doing a copy-paste of components within the same folder we normally get a popup asking if we want to paste with a different name, however, in our case we see an error message as follows:
/WebUI/Models/TCM54/Services/General.svc/CopyPasteItem failed to execute. STATUS (500): Internal Server Error The page cannot be displayed because an internal server error has occurred.
The only thing that is visible in the Event Viewer logs are warnings, which are expected (because my test VM gets them too). We don't actually see any errors other than the one in the GUI.
When copy/pasting components within a folder:
Unable to paste the item into this Folder.
Name must be unique for items of type: Component within this Folder and its BluePrint context. Source or sources of conflict: tcm:4-81455.
Error Code:
0x80040329 (-2147220695)
Call stack:
UtilitiesBL.AssertUniqueTitle
UtilitiesBL.CloneItem
ComponentBL.Clone
Tridion.ContentManager.ContentManagement.RepositoryLocalObject.Copy(OrganizationalItem,Boolean)
Tridion.ContentManager.BLFacade.ContentManagement.RepositoryLocalObjectFacade.Clone(UserContext,String,String,Boolean)
Folder.PasteItem
When copy/pasting Pages in Structure Groups:
It is not possible to paste this item into a Structure Group.
Name and File name both must be unique for items of type: Page within this Structure Group and its BluePrint context. Source or sources of conflict: tcm:5-82986-64.
Error Code:
0x80040329 (-2147220695)
Call stack:
UtilitiesBL.AssertUniqueTitleAndFileName
UtilitiesBL.AssertUniqueTitleAndFilename
UtilitiesBL.CloneItem
PageBL.Clone
Tridion.ContentManager.ContentManagement.RepositoryLocalObject.Copy(OrganizationalItem,Boolean)
Tridion.ContentManager.BLFacade.ContentManagement.RepositoryLocalObjectFacade.Clone(UserContext,String,String,Boolean)
StructureGroup.PasteItem
As mentioned above, these are normal warnings generated in the Event log, but we should be getting a popup, not the error.
We have tried restarting the server thinking it's a one-off type of quirk, but that didn't help. I understand that "TCM54" as mentioned in the error message refers to code running through COM+. Can anyone please offer some advice?
Take a look at this post: Unable to save Publication Targets in Tridion 2011 SP1
I seem to recall that pasting uses the old (COM based) code like Publication Targets do.

Why can I not compile an object in Dynamics NAV containing an OCX?

I imported a Form object from a text file. When I try to compile it I get the following error message:
This message is for C/AL programmers:
The OLE control or Automation Server identified by 'Microsoft Common Dialog Control 6.0 (SP3)'.CommonDialog requires a design time license.
This license cannot be obtained.
Make sure that the OLE control or Automation server is installed correctly with an appropriate license"
I am developing in Dynamics NAV using a developer license. The OCX is registered correctly, gets listed in NAV's "Custom Controls" as pointing to "C:\Windows\SysWOW64\comdlg32.ocx".
Why am I not allowed to compile the object?
The license in question is, as you said, purely for using the CommonDialog component in design-time environments. This has nothing to do with your NAV license or your customers being able to run code that uses the component. The design-time license (which is nothing more than a key in your system registry; not an actual license file) used to get installed with e.g. Microsoft Visual Basic 6.0 or older versions of Microsoft Visual Studio.
If you have access to VB6.0 or VS2005, you can use VB6Controls.reg on the installation disk as described here: http://support.microsoft.com/default.aspx?scid=kb;en-us;318597.
As the message said, the components loads, try to get a license and don't get one. So you don't have one as it says or you don't have it in the path lookup the components looks at it.
There is one more trick you can do to fix this problem and avoid installing a lot of crap like VB6.0.
This message is related to certain automation type variable in the object you trying to compile.
You can copy this variable from any other compiled object in other database or any other compiled object in the same database. And then your imported object will magically compile. Just delete the variable from your imported object's variable list and copy it from compiled object with copy-paste.
I don't know what magic is that but it worked for me many times. I copied variable from the same object in restored backup of the database.